Print Back
PEM Type SGPC swaging collar studs can install into most panel material, provide strong torque-out resistance and are suitable for close centerline-to-edge situations. These studs can also accommodate multiple panels as long as the total thickness does not exceed the maximum sheet thickness.

Features and Benefits
  • Installs into sheets as thin as .024” / 0.6mm.
  • Can be used to attach dissimilar materials.
  • Can be installed into most panel materials, including stainless steel and rigid non-metallic panels.
  • Allows for close centerline-to-edge distance.
  • Corrosion resistant.
  • RoHS compliant.
Unit of Measure

Specifications

Thread Size

N/A .250-20 (1/4-20)

Material Code

N/A SGPC

Thread Code

N/A 0420
L - Length ± .0151 N/A .500 in SGPC-Dwg_1.jpg
Sheet Thickness2 N/A .024 to .047 in

Hole Size in Sheet + .003 - .000

N/A .309 in

Hole Dia. of Attached Panel + .005 - .000

N/A .343 in

H ± .010

N/A .366 in
S Max.3 N/A .131 in

T ± .004

N/A .028 in
Min. Dist. Hole C/L to Edge4 N/A .250 in

Fastener Material

N/A 300 Series Stainless Steel

Standard Finish

N/A Passivated and/or tested per ASTM A380

For Use in Sheet Hardness

N/A Any

CAD Supplier

N/A PennEngineering® (PEM®)

Inventory

N/A {0}
  • 1 The “L” dimension is the height of the installed stud at max grip. The height of the stud will increase if it is installed into thinner material. To calculate “actual L” use this formula: max grip - actual grip + L = “actual L”
  • 2 See installation data for tooling requirements. Contact Technical Support (techsupport@pemnet.com) for other thicknesses.
  • 3 Threads are gageable to within 2 pitches on the “S” Max. dimension. A class 3B/5H maximum material commercial nut shall pass up to the “S” Max. dimension.
  • 4 To minimize sheet distortion and maximize product performance, use a centerline-to-edge value greater or equal to the value specified.